In-Ceiling Mount Air Curtain, 10' Environmental Seal, 3 Speed

Berner FCM In-Ceiling Mount Air Curtain, 10' Environmental Seal, 3 Speed

Free Shipping

In-Ceiling Mount Air Curtain, 10' Environmental Seal, 3 Speed
  • Product Code: 022-FCM
Please Contact
Customer Service
to Purchase
1-800-541-8683

The warranty will not be honored for residential or non-commercial use of any Commercial Equipment.

PDF

Image may not depict product color, inclusions or accessories.

Berner FCM Description

In-Ceiling Mount

Model 022-FCM

Crafted with pride in the USA

Due to the customized nature of this product a quote from customer service would be needed to insure that the customer's needs are met. The FCM air door is priced according to quote. Please use the question box at the bottom of this page or contact us by phone at 1-800-541-8683.

  • 1/2 hp three speed motor(s)
  • Galvanized steel blower wheels and housing
  • Lockable airfoil aluminum air directional vanes
  • Filter included
  • White aluminum exterior cabinet
  • Adaptable to most ceiling types
  • Recommended Protection Height / Environmental Separation - 10"
  • Recommended for openings where the door stays open or does not have a lot of traffic

Features

  • Heated / Unheated
  • Three Speed

Options

  • Unheated
  • Electric Heat
  • Steam Heat
  • Hot Water Heat

Allow 14-21 working days for delivery

See spec sheet for electrical information or contact customer service.

Warranty Info

Five year parts warranty (unheated models), Two Year (heated models)

Basic Control Package
Recommended for openings where the door stays open or does not have a lot of traffic.

Basic Package - Line Voltage Control Part No.
Unheated - 120-240V Plunger Style Switch, Remote Selector Switch 022-91ARA120BAP
Unheated - 120-240V Roller Style Switch, Remote Selector Switch 022-91ARA120BAR
Heated - 120-240V Plunger Style Switch, Remote Selector Switch 022-91ARA120BHP
Heated - 120-240V Roller Style Switch, Remote Selector Switch 022-91ARA120BAHR
*NOTE: If the total motor amp draw exceeds 20 amps and/or there are multiple manual doors
on the opening, an additional switch is needed per additional door.
Door Switch - Line Voltage Control Part No.
Basic Plunger (per additional door)* 022-9503SD020P*
Basic Roller (per additional door)* 022-9503SD020RA*


Deluxe Control Package
Recommended for high traffic openings.

Deluxe Package - 24V Voltage Control Part No.
Deluxe Unheated 120-240V - Door Switch, Factory Installed Transformer & Time Delay Relay, Remote Selector Switch 022-91ARA120DAM
Deluxe Heated 120-240V - Door Switch, Factory Installed Transformer & Time Delay Relay, Remote Selector Switch 022-91ARA120DHM
*NOTE:  If there are multiple manual doors on the opening an additional reed switch is needed
per additional door.
Door Switch - 24 volt Control Part No.
Reed Switch (per additional door)* 022-9503MRS1F2NCK*


Comfort Plus Control Package
Multispeed Heated Units Only. Provides supplemental heat when door is closed.

Comfort Package - 24 Volt Control Part No.
Comfort 120V - Door Switch Magnetic Reed, Factory Installed Transformer and Time Delay, Remote Thermostat, Remote Selector Switch 022-91ARA120PHM
Comfort 208-240V - Door Switch Magnetic Reed, Factory Installed Transformer and Time Delay, Remote Thermostat, Remote Selector Switch 022-91ARA208PHM
   To Operate 2 Units Tandem Mounted with 1 Switch
Comfort 120V-T2 - Door Switch Magnetic Reed, Factory Installed Transformer and Time Delay, Remote Thermostat, Remote Selector Switch 022-91ARA120PHMT2
Comfort 208-240V-T2 - Door Switch Magnetic Reed, Factory Installed Transformer and Time Delay, Remote Thermostat, Remote Selector Switch 022-91ARA208PHMT2


NOTE: If multiple units are installed above an opening and if the total motor hp exceeds 1-1/2 hp @ 120/1 or
3 hp @ 208/240/1 and additional speed selector switch is needed per additional unit.
Additional Selector Switch Part No.
Unheated Unit Speed Selector Switch 022-9505T324960
Heated Unit Speed Selector Switch 022-9505T324826


Electrical Accessories
Thermostat 2-Pole - Remote Mounted 022-9502DS2TP
Locking Cover for Thermostat 022-95022E999
Toggle Disconnect Remote Mounted - 30 amp 120-240V, 1O (2 hp max) 022-95083032C
Toggle Disconnect Remote Mounted - 30 amp 208-600V, 1O (2 hp max) or 3O 022-95081389C
Toggle Disconnect Remote Mounted - 40 amp 120-600V, 1O (2 hp max) or 3O 022-950840003C
Toggle Disconnect Remote Mounted - 60 amp 208-600V, 3O 022-950860303C
Factory Mounted & Wired 480/600V Transformer - Required if a single 480 or 600V power supply is required.
Includes transformer and transformer mounting bracket.
All 480V Single Motor Systems add -XH1 to model number
480V Two Motor Systems add -XH2 to model number
All 600V Single Motor Systems add -XI1 to model number
600V Two Motor Systems add -XI2 to model number

Product Specifications