In-Ceiling Mount
Model 022-FCM
Crafted with pride in the USA
Due to the customized nature of this product a quote from customer service would be needed to insure that the customer's needs are met. The FCM air door is priced according to quote. Please use the question box at the bottom of this page or contact us by phone at 1-800-541-8683.
- 1/2 hp three speed motor(s)
- Galvanized steel blower wheels and housing
- Lockable airfoil aluminum air directional vanes
- Filter included
- White aluminum exterior cabinet
- Adaptable to most ceiling types
- Recommended Protection Height / Environmental Separation - 10"
- Recommended for openings where the door stays open or does not have a lot of traffic
Features
- Heated / Unheated
- Three Speed
Options
- Unheated
- Electric Heat
- Steam Heat
- Hot Water Heat
Allow 14-21 working days for delivery
See spec sheet for electrical information or contact customer service.
Warranty Info
Five year parts warranty (unheated models), Two Year (heated models)
Basic Control Package
Recommended for openings where the door stays open or does not have a lot of traffic.
*NOTE: If the total motor amp draw exceeds 20 amps
and/or there are multiple manual doors
on the opening, an additional switch is needed per additional door.
Deluxe Control Package
Recommended for high traffic openings.
*NOTE: If there are multiple manual doors
on the opening an additional reed switch is needed
per additional door.
Comfort Plus Control Package
Multispeed Heated Units Only. Provides supplemental heat when door is closed.
NOTE: If multiple units are installed above an opening and if the total motor hp exceeds 1-1/2 hp @ 120/1 or
3 hp @ 208/240/1 and additional speed selector switch is needed per additional unit.
Electrical Accessories
Factory Mounted & Wired 480/600V Transformer
- Required if a single 480 or 600V power supply is required.
Includes transformer and transformer mounting bracket.
Recommended for openings where the door stays open or does not have a lot of traffic.
| Basic Package - Line Voltage Control | Part No. |
| Unheated - 120-240V Plunger Style Switch, Remote Selector Switch | 022-91ARA120BAP |
| Unheated - 120-240V Roller Style Switch, Remote Selector Switch | 022-91ARA120BAR |
| Heated - 120-240V Plunger Style Switch, Remote Selector Switch | 022-91ARA120BHP |
| Heated - 120-240V Roller Style Switch, Remote Selector Switch | 022-91ARA120BAHR |
on the opening, an additional switch is needed per additional door.
| Door Switch - Line Voltage Control | Part No. |
| Basic Plunger (per additional door)* | 022-9503SD020P* |
| Basic Roller (per additional door)* | 022-9503SD020RA* |
Deluxe Control Package
Recommended for high traffic openings.
| Deluxe Package - 24V Voltage Control | Part No. |
| Deluxe Unheated 120-240V - Door Switch, Factory Installed Transformer & Time Delay Relay, Remote Selector Switch | 022-91ARA120DAM |
| Deluxe Heated 120-240V - Door Switch, Factory Installed Transformer & Time Delay Relay, Remote Selector Switch | 022-91ARA120DHM |
per additional door.
| Door Switch - 24 volt Control | Part No. |
| Reed Switch (per additional door)* | 022-9503MRS1F2NCK* |
Comfort Plus Control Package
Multispeed Heated Units Only. Provides supplemental heat when door is closed.
| Comfort Package - 24 Volt Control | Part No. |
| Comfort 120V - Door Switch Magnetic Reed, Factory Installed Transformer and Time Delay, Remote Thermostat, Remote Selector Switch | 022-91ARA120PHM |
| Comfort 208-240V - Door Switch Magnetic Reed, Factory Installed Transformer and Time Delay, Remote Thermostat, Remote Selector Switch | 022-91ARA208PHM |
| To Operate 2 Units Tandem Mounted with 1 Switch | |
| Comfort 120V-T2 - Door Switch Magnetic Reed, Factory Installed Transformer and Time Delay, Remote Thermostat, Remote Selector Switch | 022-91ARA120PHMT2 |
| Comfort 208-240V-T2 - Door Switch Magnetic Reed, Factory Installed Transformer and Time Delay, Remote Thermostat, Remote Selector Switch | 022-91ARA208PHMT2 |
NOTE: If multiple units are installed above an opening and if the total motor hp exceeds 1-1/2 hp @ 120/1 or
3 hp @ 208/240/1 and additional speed selector switch is needed per additional unit.
| Additional Selector Switch | Part No. |
| Unheated Unit Speed Selector Switch | 022-9505T324960 |
| Heated Unit Speed Selector Switch | 022-9505T324826 |
Electrical Accessories
| Thermostat 2-Pole - Remote Mounted | 022-9502DS2TP |
| Locking Cover for Thermostat | 022-95022E999 |
| Toggle Disconnect Remote Mounted - 30 amp 120-240V, 1O (2 hp max) | 022-95083032C |
| Toggle Disconnect Remote Mounted - 30 amp 208-600V, 1O (2 hp max) or 3O | 022-95081389C |
| Toggle Disconnect Remote Mounted - 40 amp 120-600V, 1O (2 hp max) or 3O | 022-950840003C |
| Toggle Disconnect Remote Mounted - 60 amp 208-600V, 3O | 022-950860303C |
Includes transformer and transformer mounting bracket.
| All 480V Single Motor Systems | add -XH1 to model number |
| 480V Two Motor Systems | add -XH2 to model number |
| All 600V Single Motor Systems | add -XI1 to model number |
| 600V Two Motor Systems | add -XI2 to model number |
Product Specifications
- Printable Spec Sheet
- Crated Weight: 0.00 lbs.
- Manufacturer: Berner
- Manufacturer Part Number (MPN): FCM